Bill of materials

Project: Two-bedroom apartment, complete smart installation (France)Revision: b96beaceLanguage: ENReference standard: NF C 15-100 — to be verified

Status of this document
This project is NOT validated: it is built on a reference plan, not on a measured site. Do not use it as an execution drawing.
5 rules behind the checks are not yet verified against the applicable standard (NF C 15-100 — to be verified). Treat every protection value (cable sections, breaker ratings, residual-current devices) as “to be verified” by an authorised electrician.
Connection to the panel, commissioning and compliance are for an authorised electrician only. This document is a design guide, not a certification.

Equipment

CategoryIdItemQtyRooms
KNX and home automationK-PSUKNX power supply 640 mA1Technical node (GTL / rack) ×1
KNX and home automationK-IPKNX IP interface / router1Technical node (GTL / rack) ×1
KNX and home automationK-BRGKNX→Matter bridge for Apple Home1Technical node (GTL / rack) ×1
KNX and home automationK-ACT-DIMKNX dimming actuator, 4 channels4Technical node (GTL / rack) ×4
KNX and home automationK-ACT-SWKNX switching actuator, 8 channels2Technical node (GTL / rack) ×2
KNX and home automationK-ACT-RULKNX shutter actuator, 4 channels3Technical node (GTL / rack) ×3
KNX and home automationK-INKNX binary input module, 8 channels3Technical node (GTL / rack) ×3
KNX and home automationK-ENERGIEKNX energy meter on the main supply1Technical node (GTL / rack) ×1
KNX and home automationK-DETceiling presence and light detector7Bedroom 1 ×1; Bedroom 2 ×1; Bathroom ×1; WC ×1; Living room ×1; Kitchen ×1; Entrance / hallway ×1
KNX and home automationK-TASTAmultifunction KNX push-button14Bedroom 1 ×3; Bedroom 2 ×2; Bathroom ×1; WC ×1; Living room ×3; Kitchen ×2; Entrance / hallway ×2
KNX and home automationK-CLIMKNX gateway for air-conditioning indoor unit3Living room ×1; Bedroom 1 ×1; Bedroom 2 ×1
KNX and home automationK-CONTACTwindow/door magnetic contact11—
ProtectionK-VALVAmotorised main water shut-off valve with actuator1Technical node (GTL / rack) ×1
ProtectionK-SCURGwater leak sensor4Bathroom ×2; Kitchen ×2
ProtectionP-FUMsmoke detector (French-certified DAAF)4Bedroom 1 ×1; Bedroom 2 ×1; Living room ×1; Entrance / hallway ×1
Network and videoN-ROUTrouter / firewall with VLAN1Technical node (GTL / rack) ×1
Network and videoN-SW24-port PoE switch1Technical node (GTL / rack) ×1
Network and videoN-PP24-port Cat6A patch panel1Technical node (GTL / rack) ×1
Network and videoN-APceiling PoE Wi-Fi access point2Living room ×1; Entrance / hallway ×1
Network and videoN-CAMPoE ONVIF IP camera3Entrance / hallway ×1; Outside (entrance / balcony) ×1; Living room ×1
Network and videoN-NVRlocal NVR with storage1Technical node (GTL / rack) ×1
Network and videoN-UPSUPS for the technical node (1000 VA)1Technical node (GTL / rack) ×1
Apple Home and voiceH-HUBApple home hub (Apple TV with Ethernet)1Living room ×1
Apple Home and voiceH-VOCESiri speaker2Bedroom 1 ×1; Kitchen ×1
Air conditioningC-EXTreversible multi-split outdoor unit1Outside (entrance / balcony) ×1
Air conditioningC-INTindoor unit3Living room ×1; Bedroom 1 ×1; Bedroom 2 ×1
ShuttersR-MOTOR230 V wired shutter motor10—

Cabling and consumables

ItemQty
Cat6A cable to wall outlets10
Cat6A cable to ceiling Wi-Fi access points2
Cat6A cable to camera points3
Shutter motor cable (4×1.5 mm² or 5G1.5, as the motor datasheet says)10
Signal cable, 2 conductors, for window/door contacts11
Signal cable, 2 conductors, for leak sensors4
KNX TP bus cablelength from the plan
Spare empty conduit on each main route≥ 1
Ampera is a design guide, not a certification. Connection to the electrical panel, commissioning and compliance are the responsibility of an authorised electrician.